Certification
Our trust marks

A2P CERTIFICATION


A2P, trusted certification

for protective equipment which enhance safety and security by their reliability and resistance.

 
A2P certification is obtained after :
  • laboratory tests;
  • an audit of the production site(s).
Periodic checks are made to maintain the viability of the certification :
  • an annual audit of the production site(s).
  • laboratory evaluations (modifications, variations, etc.).

A2P certification :

  • recognises the performance and reliability of the products ;
  • guarantees their quality is recognized by safety and security professionals.

General certification reference document : A2P H0 - July 2016


A2P certification "Sprinkler Cabinets"
certifies that the products covered :
  • meet defined technical specifications (general, levels of accessibility, design and implementation),
  • are manufactured in a quality-controlled environment.

The products covered :

  • Command and control cabinets for diesel engine pumping units,
  • Command and control cabinets for electric motor pump sets.
Certification reference document : A2P H1 - Janvier 2009

A2P “automatic gas fire-extinguishing systems” certification

certifies that the products covered :
  • meet defined technical specifications (system components, technical compatibility, functional compatibility, hydraulic characteristics, efficiency),
  • are manufactured in a quality-controlled environment.

The products covered :

automatic gas fire-extinguishing systems designated by the association of the following three items
  • The gaseous extinguishing agent,
  • The storage pressure,
  • the reference of the list of components of the automatic gas extinction (AGE) system.
Certification reference document : A2P H13 - Janvier 2014
 
 

NF & A2P "Intrusion alarm systems - components" certification

certifies that the products covered :
  • meet defined technical specifications (global security level, access level and autonomy),
  • are manufactured in a quality-controlled environment.

The products covered :

  • Alarm control centres,
  • sensors (infrared, shock, opening contact, movement, etc.),
  • audible alarms, flashing light,
  • power supplies, junction boxes, intermediate equipment,
  • access control units,
  • Smoke/mist generators,

 Classification (security level) :

 
Single certification reference document : NF&A2P NF324-H58 - January 2017
NF & A2P certification is jointly issued by AFNOR Certification and CNPP Cert.
The one-stop shop is managed by CNPP Cert.

A2P "building locks" certification

certifies that the products covered :
  • Are capable of resisting unauthorized attempts at breaking and entry,
  • are manufactured in a quality-controlled environment.

The products covered :

complete building locks consisting of a main component (housing), a strike, a lock cylinder, a triangular lock cylinder and an actuator :
  • mechanically locking building locks with mechanical locking mechanism and building latches, mortised or surface-mounted, with one or more bolts, fail-safe or add-on,
  • Mechanical-cylinder or keyless building locks.

 Classification (resistance to forced entry level) :

Classification levels provide an appropriate response to the threat (burglar / tools / time typology).
A2P 1-star
Threat of the “opportunistic” type
A2P 2-star
Threat of the “burglar” type
A2P 3-star
Threat of the “professional” type
 
Certification reference document : A2P H61 - Février 2015

The A2P "Windows and building closures" certification

certifies that the products covered :
  • Are capable of resisting unauthorized attempts at breaking and entry,
  • are manufactured in a quality-controlled environment.

The products covered :

  • windows,
  • French doors,
  • shutters (double-leaf, rolling, blinds, louvers, etc.),
  • shop front security shutters (roller shutters, retractable grilles, slat shutters, rolling grilles),
  • garage doors (rolling, sliding, double-leaf, up-and-over, multi-section).

Classification (resistance to forced entry level) :

Classification levels provide an appropriate response to the threat (burglar / tools / time typology).
A2P R1
Threat of the “opportunistic” type
A2P R2
Threat of the “burglar” type
A2P R3
Threat of the “professional” type
Certification reference document : A2P H62 - Octobre 2014
 
 

The A2P "Door assembly" certification

certifies that the products covered :
  • Are capable of resisting unauthorized attempts at breaking and entry,
  • are manufactured in a quality-controlled environment.

The products covered : comprehensive and inseparable assemblies (door, door frames, pivoting member, cylinder, lock and key)

  • "home" door assemblies,
Classification levels provide an appropriate response to the threat (burglar / tools / time typology).
A2P BP1
Threat of the “opportunistic” type
A2P BP2
Threat of the “burglar” type
A2P BP3
Threat of the “professional” type
 
  • “Plant room” door assemblies.
Classification levels are expressed in accordance with the requirements of the EN1627 standard in 3 classes of increasing resistance (tools / time).
A2P CR4
Threat of the "experienced   professional" type
A2P CR5
Threat of the "experienced   professional" type
A2P CR6
Threat of the "experienced   professional" type
 
 
Certification reference document : A2P H64 - Juillet 2015

A2P "Safes and strongrooms" certification

certifies that the products covered :
  • Are capable of resisting unauthorized attempts at breaking and entry,
  • are manufactured in a quality-controlled environment.
A2P certification results in the classification of safes according to their resistance to unauthorized opening.

The products covered :

Various categories of safes for private individuals and operators of sensitive banking, industrial and commercial establishments.

Safes, strongroom doors, strongrooms, deposit systems, safe base plates

Certified characteristics include :
  • the ability to resist unauthorised attempts at entry, for a defined period of time, and deliberate attacks by one or more operators using his/her physical force and defined tools (hand tools, electrical and thermal tools as the case may be),
  • the ability of the lock intended to equip these products to resist destructive attacks and lock picking or logical opening attempts,
  • the applicable provisions of EN 1143-1 (strong boxes, ATMs, strongroom doors and strongrooms), EN 1143-2 (deposit systems).

♦ High-security locks

Certified characteristics include :
  • the ability to resist destructive attacks and lock picking or logical opening attempts,
  • the number of combinations,
  • electromagnetic compatibility,
  • reliability,
  • the applicable provisions of EN 1300 (high-security locks).

Safes for ATMs, ATM base plates

Certified characteristics include :
  • the ability to resist unauthorised attempts at entry, for a defined period of time, and deliberate attacks by one or more operators using his/her physical force and defined tools (hand tools, electrical and thermal tools as the case may be),
  • the ability of the lock intended to equip these products to resist destructive attacks and lock picking or logical opening attempts,
  • the applicable provisions of EN 1143-1 (strong boxes, ATMs, strongroom doors and strongrooms).

♦ Secure Safe Cabinets

Intelligent banknote neutralization systems built into the strong boxes and ATMs

Certified characteristics include :
  • the ability to automatically neutralize all of the banknotes irreversibly, in a given time,
  • the ability to trigger the neutralization system if attacked as defined.
Certification reference document : A2P H71 - BILINGUE - Mars 2016

Would you like to obtain A2P certification?

The application files and the associated rates are available on request from CNPP Cert., via the contact form on the certification homepage or by email to certification@cnpp.com.

In the same section:


Back to the page "Products"
"Face au risque"Magazine ListsA2P ListsAPSAD